Protocol

About Protocol

Plum devices use RS-485 standard for communication.

Each frame consists of header (7 bytes), message type (1 byte), message data (optional), CRC (1 byte) and frame end delimiter (1 byte). The minimum frame size therefore is 10 bytes.

Protocol supports unicast and broadcast frames. Broadcast frames will always have their recipient address set to 0x00, while unicast messages will have specific device address. ecoMAX controller address is 0x45, ecoSTER panel address is 0x51.

For example, we can request list of editable parameters from the ecoMAX controller by sending frame with frame type 49 and receive response with frame type 177 that contains requested parameters.

Frame structure

  • Header:
    • [Byte] Frame start delimiter. Always 0x68.

    • [Unsigned Short] Byte size of the frame. Includes CRC and frame end delimiter.

    • [Byte] Recipient address.

    • [Byte] Sender address.

    • [Byte] Sender type. PyPlumIO uses EcoNET type 48.

    • [Byte] ecoNET version. PyPlumIO uses version 5.

  • Body:
    • [Byte] Frame type.

    • [Byte*] Message data (optional).

    • [Byte] Frame CRC.

    • [Byte] Frame end delimiter. Always 0x16.

Communication

The controller constantly sends out ProgramVersion[frame_type=64] and CheckDevice[frame_type=48] requests to every known device on the network and broadcasts RegulatorData[frame_type=8] message, that contains basic controller data.

Initial exchange between ecoMAX controller (EM) and PyPlumIO library (PIO) can be illustrated with following diagram:

Sender

Receiver

Frame

Description

EM[0x45]

>

ANY[0x00]

RegulatorDataMessage

Contains ecoMAX data.

EM[0x45]

>

PIO[0x56]

ProgramVersionRequest

Program version request.

EM[0x45]

<

PIO[0x56]

ProgramVersionResponse

Contains program version.

EM[0x45]

>

PIO[0x56]

CheckDeviceRequest

Check device request.

EM[0x45]

<

PIO[0x56]

DeviceAvailableResponse

Contains network information.

EM[0x45]

>

PIO[0x56]

SensorDataMessage

Contains ecoMAX sensor data.

Note

Device network address is listed in square brackets.

Versioning

Protocol has built-in way to track frame versions. This is used to synchronize changes between devices.

Both broadcast RegulatorData[frame_type=8] and unicast SensorData[frame_type=53] frames sent by the ecoMAX controller contain versioning data.

This data can be represented with following dictionary:

frame_versions: dict[int, int] = {
    49: 37,
    50: 37,
    54: 1,
    56: 5,
    57: 1,
    61: 40767,
    80: 1,
    81: 1,
    82: 1,
    83: 1,
}

In this dictionary, keys are frame types and values are version numbers.

In example above, frame EcomaxParameters with frame type 49 has version 37. If we change any parameters either remotely or on the controller itself, the version number will increase, so PyPlumIO will be able to tell that it’s need to request list of parameters again to obtain changes.

frame_versions: dict[int, int] = {
    49: 38,  # Note the version number change.
    50: 37,
    54: 1,
    56: 5,
    57: 1,
    61: 40767,
    80: 1,
    81: 1,
    82: 1,
    83: 1,
}